These places and buildings should be equipped with

Date of release:(2019-1-24)   Click times:274
The automatic fire alarm system can be used to detect and report fire alarms in an early stage, and notify personnel to evacuate and extinguish fires in a timely manner. So, which buildings or places should be equipped with an automatic fire alarm system?
 1. The following buildings or places shall be equipped with an automatic fire alarm system:
    1. A factory building for shoes, clothing, toys, electronics, etc. with a construction area of more than 1500 m2 or a total construction area of more than 3000 m2;
    2. Each warehouse of cotton, wool, silk, hemp, chemical fiber and its products with an area of more than 1000m2, a cigarette warehouse with an area of more than 500m2 or a total construction area of more than 1000m2;
    3. Any building with a construction area of more than 1500m2 or a total construction area of more than 3,000m2, such as shops, exhibitions, financial and trade finance, passenger transportation and freight transportation, and underground or semi-underground shops with a total construction area of more than 500m2;
    4. A collection of books or cultural relics, a library with more than 500,000 books, and an important archives;
    5. Broadcasting and television buildings, postal buildings, telecommunication buildings, urban or regional power, traffic and disaster prevention command and control buildings;
    6. Principal, A, and other theaters, theaters or cinemas with more than 1,500 seats, gymnasiums or auditoriums with more than 2,000 seats, and gymnasiums with more than 3,000 seats;
    7. Children's rooms and other places in large and medium-sized kindergartens, elderly care facilities, ward buildings, hotel buildings and other children's activities in any sanatorium with a building area of more than 1500 m2 or a total construction area of more than 3000 m2, no less than 200 beds. Hospital outpatient building, ward building and surgical department;
    8. Song and dance entertainment screening entertainment venues;
    9. A technical interlayer with a net height of more than 2.6 m and more combustibles, a net height of more than 0.8 m and a smoldering top or ceiling in the form of combustibles;
    10. The main room of the electronic information system and its control room, recording medium library, machines, instruments, equipment and equipment rooms with valuable and dangerous fires, and valuables warehouses;
    11. The flammable goods warehouse with a building area of more than 50m2 and the business hall with a building area of more than 500m2 in the second-class high-rise public buildings;
    12. Other types of high-rise public buildings;
    13. Set mechanical smoke, smoke control system, rain or pre-action automatic sprinkler system, fixed fire water cannon fire extinguishing system, gas fire extinguishing system and other places or parts that need to be interlocked with the fire automatic alarm system.
    Fire detectors and sound alarm devices or fire broadcasts shall be provided for the elderly houses and their public walkways in the elderly care facilities.
2. For residential buildings with a building height greater than 100 m, an automatic fire alarm system shall be provided.
    1. For residential buildings with a building height greater than 54m but not more than 100m, an automatic fire alarm system should be installed in the public part, and a fire detector should be installed in the set.
    2. For high-rise residential buildings with a building height of no more than 54m, an automatic fire alarm system should be installed in the public part. When setting up fire protection facilities that require linkage control, an automatic fire alarm system should be installed in the public part.
    3. The public part of the high-rise residential building should be equipped with a sound alarm device or emergency broadcast with voice function.
貧匯鐙Fire Product Compliance Center 和匯鐙2016 power news of the year ten
Company address:3/floor production cencer No.58 industrial second road, national.civil aerospace industry base,_ Xi'an, Shaanxi province.
Postcode: 710100
Contact phone: 86-029-88452932
Email:1544223125@qq.com
Mobile telephone:18092305062      Fax number: 86-029-88454310
Copyright@2018 Xi'an van lag Electronics Co., Ltd.      Record number: Shaanxi ICP 18008942-1
Technical supportbtoe