Company address:3/floor production cencer No.58 industrial second road, national.civil aerospace industry base, Xi'an, Shaanxi province.
Postcode: 710100
Email:1544223125@qq.com
Contact phone: 86-029-88452932
Mobile telephone:18092305062
Fax number: 86-029-88454310
New product launch of xi 'an vanuram electronic fiDate of release:(2019-01-05) Click times:1419 |
|
AHG9600 fire alarm control system
Fire alarm control system must work continuously without interruption, and the use environment is complex and diverse, so the safety and reliability requirements of fire alarm control system are much higher than the general commercial electronic products. Xi 'an every urban ram electronics co., LTD. AHG9600 fire alarm control system integrating computer technology, network technology, distributed intelligence, automatic recognition, automatic addressing and advanced technology such as network, graphical, self diagnosis, make the system in the design, construction, commissioning, operation and maintenance easier, and many other aspects, to ensure its reliability and economy, the use of convenience is superior to other similar products. Fully meet the modern building fire alarm system for the most demanding requirements.
AHG9600 fire alarm control system advantages
01. Distributed intelligence
The system is designed with real distributed intelligent detector, built-in high-performance CPU and advanced fire criterion. Even if the controller fails, the detector itself can still give an alarm. The traditional mode that the controller analyzes and judges the sampling alarm of each detector is changed, which makes the system alarm more reliable, greatly improves the anti-interference performance of the system, and reduces the failure rate and false alarm rate.
02, intelligent image graphic monitoring
High performance industrial controller, 10.4 "TFT large screen true color LCD display, touch screen operation mode. Chinese WINDOWS graphical interface, providing clear and intuitive display of fire alarm information and convenient operation.
03. Ring bus with redundant protection
At present, most fire fighting systems adopt the bus tree wiring mode. When the disconnection fault occurs on the bus line, the alarm unit will break communication with the control machine and cannot work normally. AHG9600 system adopts advanced annular branch bus (AHGBUS). The bus has dual - terminal power supply, anti - short circuit, open circuit function, to ensure the normal operation of the system.
04. Intelligent identification and automatic addressing
All kinds of field units on AHGBUS loop can be automatically identified and programmed into the bus address by the system, and the results can be generated into the loop structure diagram. There is no need for manual writing or other electronic writing equipment, which makes debugging and daily maintenance of the system easier.
Intelligent identification and automatic addressing
All kinds of field units on AHGBUS loop can be automatically identified and programmed into the bus address by the system, and the results can be generated into the loop structure diagram. There is no need for manual writing or other electronic writing equipment, which makes debugging and daily maintenance of the system easier.
06. Radio communication
Due to the detector unit to realize the true distribution of intelligence, can the independent decision-making, analysis of authenticity fire, on-site processing system based on information loop bus AHGBUS adopting digital communication protocol, two-way broadcast communication, greatly reducing the detector and controller, the communication between the signal density all were in the pattern design of the signal processing technology to ensure the very low rate of false positives.
07, unique micro power consumption design
All detector circuits are designed with micro-power consumption devices. The static operating current of each intelligent detector is less than 80 A.
08, perfect self-diagnosis function
It can automatically monitor the power supply of main engine and standby power supply; Monitor the state of the bus circuit, accurately determine the position of short circuit and open circuit in the bus circuit, timely make isolation, double-end power supply and other measures to ensure the normal operation of the system; It can monitor the key components of the intelligent unit in real time. Reliable and complete switch design of main and standby power to ensure uninterrupted power supply of the system.
09, strong network expansion
The capacity of the system can be expanded through AHGNET among the controllers, and up to 32 controllers can be connected to the network, which can be combined into a large-scale and super-large-scale fire alarm network.
|
|